本文通过对A302B类铁素体压力容器钢室温试验的试样显微镜分析,描述材料的断裂过程并确定它与疲劳裂纹扩展数据的关系。断裂试样用了扫描电镜(SEM)、电子照相技术和能散X射线显微分析作检查。对切自T-L方向的试样的断面所作的扫描电镜检查披露了存在着在所观察倒的ΔK临界值以上时夹杂物带。随后所进行的X射线影象扫描以及目对应的能谱表明带区是硫化锰夹杂。这些试样在夹杂物带区上的裂纹扩展速度与L-T向试样相仿。产生夹
In this paper, A302B ferritic pressure vessel steel room temperature test specimen microscope analysis to describe the material fracture process and to determine its relationship with the fatigue crack growth data. Fracture specimens were examined using scanning electron microscopy (SEM), electrophotography and X-ray powder analysis. Scanning electron microscopy of the cross-section of the specimen cut in the T-L direction revealed the presence of inclusions bands above the observed ΔK cutback. Subsequent X-ray image scans and the corresponding spectra showed that the band was manganese sulfide inclusions. The crack growth rate of these samples in the inclusion zone is similar to that of the L-T sample. Produce clips