以中国银行总部大厦的设计为例,突破常规,提出不设沉降缝的探索和创新,试图说明在具有多层地下室的情况下,虽然上部结构荷载差异较大,仍可不设沉降缝的问题。实践证明,结果十分成功,并认为可作为今后类似工程的设计趋向与参考
Taking the design of Bank of China Headquarter Building as an example, this paper breaks through the routine and puts forward the exploration and innovation without settlement joint. This paper attempts to show that there is still no need for settlement joints in the case of multi-storey basement, although the load of superstructure is quite different. Practice has proved that the result is very successful and can be used as a design trend and reference for similar projects in the future