应用二维超声心动图(2-DE)检出室间隔缺损,房间隔缺损及动脉导管未闭等三类间隔缺损先心病共73例,经手术证实,术前2-DE诊断符合率100%。统计学分析表明,2-DE确定动脉导管未闭和室间隔缺损口的大小,与术中实测相比,相关性好(γ分别为0.98和0.90,P均<0.01),但对确定房间隔缺损大小的相关性较差(γ=0.62,P>0.05),作者详细分析了造成2-DE测量误差的原因及其改进办法。
Two-dimensional echocardiography (2-DE) detected ventricular septal defect, atrial septal defect and patent ductus arteriosus and other three types of septal defect congenital heart disease in 73 cases, confirmed by surgery, preoperative 2-DE diagnosis coincidence rate of 100% . Statistical analysis showed that 2-DE to determine the size of patent ductus arteriosus and ventricular septal defect compared with the measured intraoperative, the correlation was good (γ = 0.98 and 0.90, P <0.01) However, the correlation between the size of atrial septal defect and the size of atrial septal defect was poor (γ = 0.62, P> 0.05). The author analyzed in detail the causes of the 2-DE measurement error and the improved methods.