Multi-sensor information fusion based control for VAV systems using thermal comfort constraints

来源 :建筑模拟(英文版) | 被引量 : 0次 | 上传用户:zhoufuhai5933
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
The conventional control methods of variable air volume (VAV) air conditioning systems usually assume that the indoor air is well mixed, and consider each building zone as one node with homogeneous temperature distribution. The average temperature is subsequently used as the controlled parameter in the VAV cascade control process, which might cause uneven temperature distribution and unsatisfactory thermal comfort. This paper presents a coupled simulation of computational fluid dynamics (CFD) and building energy simulation (BES) for the VAV system in an office building located in Shanghai for the purpose of simulating the building, the VAV control system, and indoor thermal environment simultaneously. An external interface is developed to integrate the CFD and BES models based on quasi-dynamic coupling approach. Based upon the developed co-simulation platform, the novel VAV control method is further proposed by fusing information from multiple sensors. By adding two temperature sensors to constrain the thermal comfort of the occupied zone, the supply air temperature setpoint of the VAV terminal unit can be reset in real time. The novel control method is embedded into the co-simulation platform and compared with the conventional VAV control approach. The results illustrate that the temperature distribution under the proposed method is more uniform. At most times of the typical test day, the air diffusion performance indexes (ADPIs) for the proposed method are above 80%, while the ADPIs for the conventional control method are between 60% and 80%. Due to multi-sensor information fusion, the proposed VAV control approach has better ability to ensure the indoor thermal comfort.
其他文献
The indoor parameters are generally non-uniform distributed. Consequently, it is important to study the space cooling/heating load oriented to local requirement
Evidence indicates that improvement of thermal performance of building envelope has the potential for aggravating the indoor overheating risk in summer. On the
A computational research of radiative-convective energy transport in large-scale enclosure with a heat-generating heater under normal room conditions has been c
Particulate matter emission from rotating wheels, which imparts a force to the contact surface and causes strong air currents, is one of the important pollutant
随着节能标准的不断提升,节能造价成本也随之增多;设计人员对建筑节能知识、相关标准理解不到位,设计时保守意识较为严重,对节能新技术新产品不够了解,造价成本不够熟悉,造成节能方案成本偏高的情况。文章通过对节能造价成本与相关节能设计标准及规范的解读,分析节能优化设计的原则,总结概括了节能优化设计管控措施,形成设计优化策略,以期对EPC项目设计阶段成本控制具有一定的指导意义。
A temperature-based method is usually applied in displacement ventilation (DV) design when overheating is the primary indoor climate concern. Different steady-s
The goal of this study is to investigate the effect of key design parameters on the thermal performance of the packed bed heat storage device by numerical calcu
Curtain walls are more and more commonly used as building facades. They allow a better daylight availability and a direct connection to exterior environments. M
In countries suffering from heavy ambient air pollution, ventilation is a problem, as ventilation intakes outdoor air pollutants, such as particulate matter wit
The design of urban squares in the city of Mendoza, Argentina, is based on aesthetic and landscaping criteria without consider strategies to enhance the benefit