1985年,我们对尚志水泥厂的供热工程系统进行了现场技术改造设计。运行结果表明,供热效果良好,经济效益显著,但从中也发现目前一些中小型供热系统中,尤其中小城市和县城供热系统中存在着严重问题,最根本的是设计中存在问题。 一、尚志水泥厂供热系统 尚志水泥厂主要供热负荷是采暖和一个浴池的热水供应。需要采暖的建筑总面积约34900m~2。其中平房和单层高大厂房约占1/4,所有需要采暖的建筑都围绕生产车间
In 1985, we conducted on-site technical renovation of the Shangzhi Cement Plant’s heating engineering system. The results of the operation show that the heating effect is good and the economic benefits are significant. However, it has also been found that there are serious problems in some small and medium-sized heating systems, especially the small and medium-sized cities and the county heating systems. The most fundamental problem is that there are problems in the design. I. Heating system of Shangzhi Cement Plant The main heating load of Shangzhi Cement Plant is heating and a hot water supply for a bath. The total area of buildings requiring heating is approximately 34,900m2. One-fourth of the bungalows and one-storey tall buildings are located, and all buildings requiring heating are built around the workshop.