我公司一台SHF20t/h沸腾炉1989年底投运后仅8个月,就发现对流区尾部的管束严重磨损,不足1年,就因磨损而爆管,不得不停炉,磨损速度之快,实属罕见.经分析发现,1.运行工况与设计工况不符,在实际蒸发量为25t/h时,对流区的狭窄处与拐点处(如自1)烟气流速达18m/s,大大超过了14m/s最高烟气流速的推荐值.2.掺烧的煤渣飞灰含量大,取样分析为17000mg/m~3,加速了对流区管束的磨损.
I SHF20t / h a boiling furnace company put into operation at the end of 1989 only eight months, we found that the tail of the convection section of the tube serious wear and tear, less than 1 year, due to wear and tear tube, had shutdown, wear faster, the real Is rare.Analysis found that 1. Operating conditions and design conditions do not match, the actual evaporation of 25t / h, convection area at the narrow and inflection point (as from 1) flue gas flow rate of 18m / s, greatly Exceeding the recommended value of the maximum flue gas velocity of 14m / s. 2. The content of fly ash mixed with coal is large, and the sample analysis is 17000mg / m ~ 3, accelerating the wear of the convection zone tube bundle.