论文部分内容阅读
首先用碱熔融法分解试样,然后加抗坏血酸将试液中的Fe3+还原为Fe2+,再用离子色谱法测定试液中的Fe2+,Mg2+和Ca2+。采用Shim-packIC-Cl阳离子交换柱分离样品离子,以0.25mmol/L乙二胺-0.50mmol/L柠檬酸(pH4.50)为流动相,以CDD-6A电导检测器检测,使被测组分得到满意的分离和检测。Fe,Mg和Ca的加标回收率均在90%以上。测定结果与原子吸收光谱法测定结果相近。
Firstly, the sample is decomposed by the alkali melting method, then the ascorbic acid is added to reduce the Fe3 + in the test solution to Fe2 +, and then the Fe2 +, Mg2 + and Ca2 + in the test solution are determined by ion chromatography. The sample ions were separated on a Shim-pack IC-Cl cation exchange column and eluted with 0.25 mmol / L ethylenediamine-0.50 mmol / L citric acid (pH 4.50) as mobile phase and CDD-6A conductivity detector Test components were satisfactorily separated and tested. The spiked recoveries of Fe, Mg and Ca were over 90%. The results are similar to the results of atomic absorption spectrometry.