CIAE的HI-13串列加速器投入运行以来的头四年时间内,共累积供束13000多h。本文详细描述了四年运行过程中串列加速器的工作状况。其最高的头部运行电压为12.6MV,最低的头部运行电压为2.08MV,已经有近二十多种粒子束通过了串列加速器,完成了多项很有意义的物理实验工作。在加速器运行的这头四年时间内积累了大量宝贵的运行经验,诸如安装、测试、组调输电梯、高压锻炼、调束供束等。成功地解决了在运行维修中出现的各种故障。
During the first four years since CIAE’s HI-13 Tandem Accelerator was put into operation, a cumulative supply of more than 13,000 h was provided. This article details the working status of Tandem Accelerator during four years of operation. The highest head operating voltage of 12.6MV, the lowest head operating voltage of 2.08MV, nearly twenty kinds of particle beam through the tandem accelerator, completed a number of meaningful physical experiments. During the first four years of operation of the accelerator, a great deal of valuable operational experience has been accumulated, such as installation, testing, group transfer elevators, high-pressure workouts, beam adjustments and more. Successfully solved the operation and maintenance in the emergence of various failures.