介绍了1次作为真空容器的凝汽器的水位测量偏差缺陷消除的过程。由于常规的消缺办法无法奏效,通过观察总结出隐含规律,并依据理论分析和公式计算找出故障范围和原因,在不影响机组安全运行的基础上消除了缺陷。
The process of eliminating defects of water level measurement of condenser as a vacuum container was introduced. Because conventional methods of eliminating and eliminating defects can not work, the implicit laws are concluded through observation and the scope and causes of faults are found out based on theoretical analysis and formula calculation. The defects are eliminated on the basis of not affecting the safe operation of the generating units.