【摘 要】
:
Measuring the microscopic temperature of graphene is challenging. We used cholesteric liquid crystal microcapsules (CLCMs) as temperature sensors to detect the local temperature of three-dimensional porous graphene through quantitative visualization. Base
【机 构】
:
CollegeofElectronicandOpticalEngineering
【出 处】
:
ChineseOpticsLetters
论文部分内容阅读
Measuring the microscopic temperature of graphene is challenging. We used cholesteric liquid crystal microcapsules (CLCMs) as temperature sensors to detect the local temperature of three-dimensional porous graphene through quantitative visualization. Based on a CLCM (~20 μm in size), we determined the temperature variation in a small area with an accuracy of 0.1°C. By analyzing the color changes between two CLCMs, we demonstrated the temperature changes dynamically in a region with a diameter of approximately 110 μm. Furthermore, by comparing the color evolution among the three CLCMs, we visualized the anisotropic thermal properties in the micro-zone. This convenient and low-cost temperature measurement method is expected to further improve graphene-based devices.
其他文献
利用改进的强场近似方法分析了长程势以及短程势在阈上电离能谱中的贡献, 确定了能谱中低能结构的起因。同时, 为了确定在计算电子与分子离子散射截面时用纯分子代替分子离子是否合理, 计算了不同入射电子能量条件下, 电子和原子离子弹性散射的微分散射截面。理论计算和实验结果表明在入射电子能量较大时, 长程势在激光诱导的电子离子大角度背向散射时的影响可以忽略, 证明了在大角度散射时, 用纯分子来代替分子离子是合理的。
Asymmetrically clipped optical orthogonal frequency division multiplexing (ACO-OFDM) has been a promising candidate in visible light communications (VLC) due to its improvement in power efficiency and reduction of nonlinearity based on previous simulation
The emergence of new materials can push scientific development and even lead to a new industrial revolution. The discovery of graphene has attracted more and more attention from society due to their excellent optics and electricity properties. Graphene
为解决6D激光标靶在受非引力外力作用的环境下姿态测量失效的问题,提出了一种基于激光标靶和捷联惯导系统(SINS)的组合位姿测量方法。通过推导卡尔曼滤波状态方程与观测方程,建立组合测量系统的卡尔曼滤波模型,利用卡尔曼滤波校正位姿误差和惯性测量单元(IMU)随机误差。在卡尔曼滤波模型中加入故障检测方法,使组合系统具有自监控功能。当激光标靶姿态失效时,仅使用校正后的SINS数据,保证系统的可靠性。最后,对所提方法进行仿真验证。仿真结果表明,该方法能有效地解决激光标靶姿态角测量失效问题,提高系统抗干扰性和动态性能
In order to measure the shock initiation behavior of JOB-9003 explosives, Al-based embedded multiple electromagnetic particle velocity gauge technique has been developed. In addition, a gauge element called the shock tracker has been used to monitor the p
The antitumor efficiency of gold nanorod plasmonic photothermal therapy (PPTT) was evaluated experimentally. The rat cholangiocarcinoma line PC-1 was used as a tumor model. Exposure of tumors to 808-nm laser radiation was performed, and the noninvasive te
对磷锗锌晶体光学薄膜激光损伤的机理进行了实验和理论研究。将同一批生长的磷锗锌晶体切割为6 块,并利用相同的工艺对这些晶体进行抛光;对其中4只样品镀制双波段多层增透膜,利用扫描电子显微镜观察这4只样品的光学薄膜形貌,发现薄膜的大部分区域成膜质量较好,但也有小部分区域形成团簇;利用二次离子质谱仪分析了薄膜的组成成分,发现在该薄膜的ZrO2层含有Pt元素;利用波长为2 μm、脉宽为31 ns的固体激光器对磷锗锌晶体样品进行激光损伤阈值测试,得出4只镀膜样品的激光损伤阈值平均值为0.68 J/cm2,其他2只未镀
We present two optimal schemes for non-local implementing a single-qubit rotation operation via a maximally entangled quantum channel. We report on the quantitative relations between the quantum action, entangled and classical communication resources requ
红外探测器光学元件表面疵病、污染可能会降低系统的探测性能。杜瓦中窗片、滤光片表面存在不同程度的麻点、划痕,采用光学仿真软件LightTools计算分析光学元件表面不同疵病等级情况下的光学参数,引入杂散辐射系数和信杂比的概念对杜瓦光学特性进行评估,合理判断光学元件的表面疵病容限。同时仿真分析滤光片位置造成的表面疵病对杜瓦光学特性的影响。结果表明:随着窗片、滤光片表面疵病等级增加,接收像面非均匀性增加、信号强度减弱,且在相同疵病等级情况下,滤光片与芯片距离越近,疵病对杜瓦光学特性影响越大,因此在杜瓦设计时必须
对于普通单模光纤的布里渊散射光,其频移是温度或应变的函数,因此通过检测布里渊频移可得到沿光纤分布的温度或应变。但布里渊散射分布式光纤传感器有光时域分析和光时域反射计两种结构,两者具有不同的性能特点和使用场合,在实际传感应用中需要加以选择,用以实现有效的长距离光纤传感。如何在一个系统中融合这两种分布式光纤传感技术,其关键是产生传感所需的频移参考光或探测光。采用光纤激光器作为单一光源,基于微波电光调制