我厂低温电站的1~#减温减压器在一次切换操作时,发出投用信号后,虽然减压阀的气动执行机构动作了,但减温减压器却不起作用,无法承担热负荷.解体后发现减压阀阀杆在阀芯与阀芯提升杆连接处断裂,阀芯脱落,从而导致1~#减温减压器无法投用.1.减压阀结构减压阀结构示意见图1,主要由阀体、阀杆衬套、杠杆、气动执行机构等零部件组成.其动作过程是,气动执行机构5根据蒸汽热网用户的用汽量变化而动作,并通过杠杆4将阀杆2提起或放下,从而改变了蒸汽室出口的开度,使阀门出口压力发生变化,并与减压阀出口端的节流孔板共同作用,达到降低压力的目的.
I cryogenic power plant plant 1 ~ # reducer in a switching operation, after the signal is put into operation, although the pneumatic valve actuator action, but the temperature reducer does not work, can not afford to heat Load. Disintegration and found that the valve stem in the spool and valve lift rod fracture Department, spool off, resulting in 1 ~ # can not be put into use reducing pressure regulator .1. Pressure reducing valve structure Pressure reducing valve structure Figure 1, mainly by the valve body, stem bushing, lever, pneumatic actuator and other components.Its action process is that the pneumatic actuator 5 according to the steam heat network user changes in the amount of steam and action, and through the lever 4 lift the valve stem 2 or down, thereby changing the steam chamber outlet opening, the valve outlet pressure changes, and the outlet valve with the relief valve work together to achieve the purpose of reducing pressure.