电热温床在我国蔬菜、花卉和果药等生产上的应用面积越来越大,仅用于蔬菜育苗累计有一百万亩左右。在应用过程中,因各种原因导致电器设备故障而影响正常应用的情况时有发生。如出现故障可按下述方法进行排除。一、控温仪故障分析及维修 1.继电器烧坏。BKW型和KWD型控温仪的后面有两个接线柱,电源的火线和零线误接,则会造成控温仪的继电器烧坏。 2.旋动控温仪旋钮,指示灯不交替发亮。其原因:①感温头损坏、引线断线或没插在控温仪上;
Electrothermal hotbeds are increasingly used in the production of vegetables, flowers, and fruits in China. They only have a total of about one million mu of vegetable seedlings. In the application process, the occurrence of electrical equipment failure due to various reasons and affect the normal application of the situation occurs. If it fails, it can be eliminated as follows. First, temperature controller fault analysis and maintenance 1. Relay burn out. There are two terminals behind the BKW and KWD temperature controllers. If the power and the neutral wires of the power supply are mis-connected, the relay of the temperature controller will burn out. 2. Rotate the knob of the temperature controller and the indicators do not light alternately. The reasons are: 1 The temperature sensor is damaged, the lead wire is disconnected or not inserted in the temperature controller;