松软煤层小煤柱动压巷道支护技术研究及实践

来源 :煤炭技术 | 被引量 : 0次 | 上传用户:blusky
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
为解决松软煤层小煤柱动压巷道支护的技术难题,以漳村矿2202工作面回风巷作为研究背景,通过相似模拟实验对采动压力作用下的松散煤层巷道变形破坏特征进行了研究,在此基础上,对回采巷道合理的支护方式及支护参数进行了设计。并通过FLAC3D数值模拟和工业试验验证了其方案能够有效地控制松软煤层小煤柱巷道围岩的变形。 In order to solve the technical problems of soft coal seam with small coal pillar dynamic pressure and roadway support, taking the air return tunnel of 2202 working face of Zhangcun Mine as a research background, the deformation and failure characteristics of loose coal seam roadway under mining pressure were studied through similar simulation experiments On this basis, the reasonable support mode and supporting parameters of the mining roadway are designed. Through the FLAC3D numerical simulation and industrial test, the scheme can effectively control the deformation of surrounding rock of coal pillar with loose coal pillar in soft coal seam.
其他文献
期刊
2月8日,消息称日本商船三井(MOL)已开始对去年6月遭遇厄运的8100箱集装箱船“MOL Comfort”号的建造者三菱重工(MHI)采取法律行动。日本船级社(ClassNK)检验发现,“MOL Comfort”轮的六艘姊妹船船底外板“纵向屈曲变形”,商船三井据此将三菱重工诉至东京地方法院,要求对方补偿加强6艘姊妹船船体所需的费用。如果索赔成功,该案将有可能对跟这艘集装箱船相关的其他数千个诉讼产
应用可拓分析研究了数控设备故障停机率降低策略。引入关联函数计算关联度,并采用自顶向下分析法确定权重系数,得出数控设备重要程度等级,以此确定数控设备故障停机率降低策
特高压(ultra high voltage,UHV)气体绝缘开关设备(gas insulated switchgear,GIS)的瞬态外壳电压(transient enclosure voltage,TEV)具有陡波前、高幅值和宽频带等特点,可能
本文通过对荣华二采区10
期刊