下面推荐的步骤可解决屏蔽中所遇到的问题:1.最大限度地减少外壳结构中的接缝;利用原有的金属结构如磁盘机基座板作为屏蔽系统的一部分;去掉自由浮动的金属件.2.在可拆卸的不连续点处,用RF屏蔽垫来进行密封.3.在设计门、盖板和检修孔的面板时,应使屏蔽垫承受的压力可以控制.选用的屏蔽垫应具有最小的压缩力和最大的工作高度范围.使用主动止动器.4.门和检修孔面积采用刀边或锅边的面板结构.5.尽可能使用最大的屏蔽垫.6.为避免损坏,作为剪切垫用的钩爪自由端应当闭合.7.安装屏蔽垫时应最大限度地减少发生障碍的可能性,在应用于门的屏
The following recommended steps to solve the problems encountered in shielding: 1. To minimize the seam in the shell structure; the use of the original metal structures such as disk drive base plate as part of the shielding system; remove the free floating metal 2. At the point of disassembly and discontinuity, use an RF shielding pad to seal 3. The pressure applied to the shielding pad should be controlled during the design of the door, cover and access panel. Should have minimal compression and maximum working height range. Use active stop .4 door and manhole area using the knife edge or pan side panel structure .5 as far as possible the use of the largest shielding pad .6 to avoid Damaged, the free end of the claw used as a shear pad should be closed .7. Shielding pads should be installed to minimize the possibility of obstacles, applied to the door screen