论文部分内容阅读
我院外科与工厂合作,设计、自制成Z-CI型腹腔-静脉转流装置(简称装置)。经10只狗,1只恒河猴缩窄膈上的下腔静脉制造腹水动物模型,然后安装本装置,证明其性能及效能良好,乃应用于临床。我院对48例肝硬变重度腹水患者应用本装置进行了腹腔一静脉转流术。年龄21—56岁,腹水病程1 1/2~20年,腹围89~128厘米。治疗结果:全组均于8—14天腹水消退,术前腹大如鼓,行走蹒跚,术后腹水消退,腹围明显缩小,尿量明显增多。术后食
Our hospital surgery and factory cooperation, design, self made Z-CI type of celiac - venous bypass device (referred to as device). The animal model of ascites was made by narrowing the inferior vena cava on the diaphragm with 10 dogs and 1 rhesus monkeys. Then, the device was installed to prove its performance and efficacy, which was applied to clinic. 48 cases of cirrhotic patients with severe ascites in our hospital using this device for abdominal a venous bypass. Age 21-56 years, ascites course 1 1/2 to 20 years, abdominal circumference 89 to 128 cm. Treatment outcome: The whole group were ascites subsided in 8-14 days, abdomen as large as the drum before surgery, walking faltering, postoperative ascites subsided, abdominal circumference was significantly reduced, urine output increased significantly. Postoperative food