沿海某地区的一处地下钢筋混凝土管道工程渗漏水比较严重,多处地段长年积水。尽管不间断地用水泵排水,但地沟内仍有地下水渗入,影响地沟的正常使用。一、渗漏原因1.该地区地下水位较高,管沟外壁常年浸泡在地下水中。2.施工时降水不到位(基槽底以下0.3米),有时为了抢工期,不等基槽内的水排净就浇筑混凝土,把防水混凝土当成水下混凝土施工。
The leakage of an underground reinforced concrete pipeline project in a certain area along the coast is serious, and there are many years of accumulated water. Despite continuous water pumping, there is still groundwater infiltration in the trench, affecting the normal use of the trench. I. Causes of leakage 1. The groundwater level in the area is high, and the outer wall of the trench is soaked in groundwater all year round. 2. During construction, precipitation is not in place (0.3 meters below the bottom of the foundation tank). Sometimes, in order to grab the construction period, the concrete in the base tank is poured out and the concrete is poured. The waterproof concrete is used as underwater concrete construction.