在 DTL—121调节器中,相互干扰系数F 对于调节器的实际积分时间 T_I 究竟有无影响?在这一问题上存在不同的看法。参考资料[1]认为不论 F 为何值,恒有 T_I=T_I,并对此进行了理论上的论述和实验验证。文章在进行理论论证和实验结果分析时,都是把 F≠1时的积分输出和 F=1时的比例输出相比较,二者达到相等所经历的时间即视
In the DTL-121 regulator, mutual interference coefficient F for the regulator actual integration time T_I whether there is any impact? There is a different view on this issue. Reference [1] that no matter what the value of F, constant T_I = T_I, and this theoretical discussion and experimental verification. When the theoretical argumentation and the experimental results are analyzed, the article compares the integral output when F ≠ 1 with the proportional output when F = 1,