放射作业人员584名晶状体混浊情况调查

来源 :职业与健康 | 被引量 : 0次 | 上传用户:liyuan04981
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
目的 探明X线作业人员晶状体混浊情况。方法 采用裂隙灯检查法对本市584名X线作业人员晶状体进行调查。结果 584人中放射性白内障11人,检出率为1.88%,“放射性晶状体损伤”所致晶状体混浊的检出率明显高于对照组(P<0.01),医用X线和工业探伤人员晶状体混浊情况差异无显著性(P>0.05),X线作业人员晶状体混浊的检出率随工龄增长而增高。结论 X线作业人员晶状体混浊程度与接触射线的时间及防护条件有关。 Objective To determine the opacity of lens in X-ray workers. Methods Slit lamp examination was performed on 584 X-ray workers in our city. Results There were 11 out of 584 patients with radioactive cataract, the detection rate was 1.88%. The detection rate of lens opacity caused by “radioactive lens injury” was significantly higher than that of the control group (P <0.01). The opacity of lens in medical X- The difference was not significant (P> 0.05), X-ray ophthalmic workers opacity detection rate increased with the increase of seniority. Conclusion The degree of lens opacity of X-ray workers is related to the exposure time and the protective conditions.
其他文献
首先对影响地面气象测报数据异常的原因和处理办法进行分析,然后提出加强新业务培训学习、严格监管规章制度等几点建议,有利于提高地面气象测报工作整体质量。
期刊
2013年7月5-7日,湖北省武汉市出现连续暴雨到大暴雨天气。基于此,利用武汉区域自动站、武汉站地面以及高空观测资料、Micaps数据等资料,对暴雨发生期间的环流形势、各层系统高低
期刊
期刊
期刊
期刊