提出了一种利用安装在高炉炉衬外表面的多极板电容传感器阵列检测高炉炉衬侵蚀状况的新方法。有限元仿真研究结果表明,炉衬的侵蚀状况与传感器的输出值密切相关。该方法可为高炉炉衬侵蚀状况的监测提供一种牢固可靠、非侵入式的新手段
A new method to detect the erosion condition of blast furnace lining by using the multi-plate capacitive sensor array installed on the outer surface of the blast lining is proposed. Finite element simulation results show that the erosion of the lining is closely related to the output of the sensor. The method can provide a solid, reliable and non-invasive new method for the monitoring of blast furnace lining erosion