新疆油田油气储运分公司彩南增压站目前使用的两台DPC-2804压缩机组,受夏季冷却水温度偏高、冬季级间缓冲罐至仪表盘的引压管道冻堵的影响,造成仪表故障和机组停机。为此,在研究分析机组设计组成的基础上,采取加强仪器仪表的检测更新、添加高效冷却液、加装防冻缓冲罐、强化保温等一系列措施,稳定冷却水温,减少了引压管道冻堵,降低了压缩机的故障停机率,保障了机组的正常运行,在油田往复式压缩机装置中得到了推广应用。
Two DPC-2804 compressors currently used in the Cai Nan Booster Station of Xinjiang Oilfield Oil and Gas Storage and Transportation Branch are affected by the high temperature of the cooling water in summer and the freezing blockage of the pressure piping from the buffer tank to the instrument panel in the winter stage, Failure and shutdown of the unit. Therefore, on the basis of the research and design of the unit design, a series of measures such as testing and updating of instrumentation, adding efficient cooling fluid, installing antifreeze buffer tank, strengthening insulation and so on are adopted to stabilize the cooling water temperature and reduce the freezing blocking , Reducing the compressor downtime rate to ensure the normal operation of the unit in the oil field reciprocating compressor device has been popularized and applied.