【摘 要】
:
Airborne transmission is an important mechanism of spread for both viruses and bacteria in hospitals, with nosocomial infections putting a great burden on publi
【机 构】
:
School of Public Health, Guangdong Pharmaceutical University, Guangzhou, Guangdong 510310, China;Sta
论文部分内容阅读
Airborne transmission is an important mechanism of spread for both viruses and bacteria in hospitals, with nosocomial infections putting a great burden on public health. In this study, we designed and manufactured a bed for pediatric clinic consultation rooms providing air isolation to protect patients and medical personnel from pathogen transmission. The pediatric isolation bed has several primary efficiency filters and a high-efficiency particulate air filter in the bedside unit. The air circulation between inlet and outlet forms negative pressure to remove the patient''s exhaled air timeously and effectively. A computational fluid dynamics model was used to calculate the speed of the airflow and the angle of sampler. Following this, we conducted purification experiments using cigarette smoke, Staphylococcus albus (S. albus) and human adenovirus type 5 (HAdV-5) to demonstrate the isolation efficacy. The results showed that the patient''s head should be placed as close to the air inlet hood as possible, and an air intake wind speed of 0.86 m/s was effective. The isolation efficacy of the pediatric isolation bed was demonstrated by computational fluid dynamics technology. The isolation efficiency against cigarette smoke exceeded 91.8%, and against S. albus was greater than 99.8%, while the isolation efficiency against HAdV-5 was 100%. The pediatric isolation bed could be used where isolation wards are unavailable, such as in intensive care units and primary clinical settings, to control hospital acquired infections.
其他文献
In the Canadian north, the cost of space heating is very high due to the harsh weather, its remoteness, lack of transportation, and dependency on the high cost
随着社会经济的进步发展以及城市化进程的不断加快,建筑行业也得到了迅速的发展,各种新材料、新技术的应用也最大限度上满足了人们对现代建筑的要求.其中施工技术的应用效果,
Evacuation systems in buildings are frequently assessed to improve emergency response processes. This paper proposes a method to evaluate the performance of dif
Due to the different approaches in determining the ventilation airflow rate per person for workspaces, where high-temperature air conditioning systems are used
It is well known that the passive strategies applying in traditional buildings respond satisfactory to climatic requirements and succeed to provide maximum indo
Central air-conditioning systems predominantly operate under partial load conditions. The optimization of a differential pressure setpoint in the chilled water
Numerical studies on internal fire whirls (IFW) generated in a vertical shaft model with a single corner gap were reported in this paper. The generation of IFW,
Indoor air dynamics and quality in high density residential buildings can be complex as it is affected by both building parameters, pollution sources, and outdo
Public buildings such as libraries consume a vast amount of cooling energy for maintaining a comfortable and stable indoor environment in summer, especially in
Buildings can be operated in an energy-flexible manner while respecting occupant thermal comfort. This energy flexibility of building operations, both in time a