论文部分内容阅读
12.5系列制冷压缩机的油耗量超过标准问题过去曾是制造厂在产品出厂时较为普遍遇到的问题,产量较大的制造厂如上海第一冷冻机厂、烟台冷冻机厂等在结构进行改进后,都早已攻克了这一技术关键。作者所介绍的2AV—12.5制冷压缩机由于结构未曾改进致仍出现油耗偏大问题,虽此产品为数不一定很多,但对用户来说使用中就感非常棘手。作者能在维修过程中找出问题予以解决并投稿本刊,我们对此表示欢迎,特刊登以供有类似问题的使用单位参考,同时也希望读者能将设计、制造、安装、操作、维修等方面的经验投稿本刊。
12.5 Series Refrigeration Compressor Oil Consumption Exceeds the Standard Problem In the past, the manufacturer had more problems with the factory when the product was shipped. The larger manufacturers such as Shanghai No.1 Freezer Factory and Yantai Freezer Factory were improved in structure After all, have overcome this key technology. The 2AV-12.5 refrigerant compressor that the author introduces still causes the problem of excessive fuel consumption because of the structure has not been improved, although this product may not be quite large in number, but it is very tricky for the user to use. The author can identify problems in the maintenance process to solve and contribute articles, we welcome this, special published for similar use of the unit for reference, but also hope that the reader will be able to design, manufacture, installation, operation, maintenance, etc. The contribution of experience in this issue.