采用电化学动电位再活化法(EPR法)测得的反向扫描电流的最大值与正向扫描电流的最大值的比值(Ir/Ia)评价去应力处理和未处理的堆焊不锈钢复合板00Cr17Ni14Mo2/20R复层晶间敏感性,并与传统的H2SO4-CuSO4-Cu法结果进行了对比.结果表明:EPR法能定量、定性地检测不锈钢的晶间腐蚀敏感性,与传统H2SO4-CuSO4-Cu法试验结果相吻合;对堆焊不锈钢复合板00Cr17Ni14Mo2/20R进行(610±10)℃的去应力处理,将导致不锈钢复层的晶间敏感性,EPR法电流比值Ir/Ia达到37.5%,H2SO4-CuSO4-Cu法晶间腐蚀后弯曲,在弯曲外表面产生许多交叉小裂纹.
The ratio of the maximum value of the forward scan current and the maximum value of the forward scan current (Ir / Ia) measured by the EPR method was used to evaluate the stress-relieved and untreated surfacing stainless steel clad plates 00Cr17Ni14Mo2 / 20R composite layer intergranular sensitivity and compared with the results of the conventional H2SO4-CuSO4-Cu method.The results show that: EPR method can quantitatively and qualitatively detect stainless steel intergranular corrosion sensitivity, and the traditional H2SO4-CuSO4- (610 ± 10) ℃, the intergranular sensitivity of the stainless steel clad layer will result. The current ratio Ir / Ia of EPR method reaches 37.5% H2SO4-CuSO4-Cu intergranular corrosion after bending, in the curved outer surface of many cross-cracks.