作者为了测定~(99m)Tc-硫胶体和~(99m)Tc-微白蛋白胶体在正常人体内的分布和重复性对20例正常人每人用两种显象剂作过曝光延迟模拟显象和延迟数字显象。结果如下: 模拟显象:在过曝光前位胸部显象时,用~(99m)Tc-硫胶体发现20例中有19例(95%)有肺灌注摄取,甲状腺无放射性。用微白蛋白胶体却无一人有肺摄取,甲状腺每例均有放射性。在一般曝光前位显象时,用~(99m)Tc-硫胶体也发现肺有30%(6/20)轻度摄取,而微白蛋白胶体无一例
In order to determine the distribution and reproducibility of ~ (99m) Tc-sulfur colloids and ~ (99m) Tc-microalbumin colloids in normal human subjects, 20 normal subjects Like and delay digital display. The results were as follows: Simulated visualization: In the anterior chest imaging of overexposure, 19 (95%) of the 20 patients were found to have pulmonary perfusion in ~ (99m) Tc-sulfur colloids, with no thyroid gland. With microalbumin gel but no one has a pulmonary uptake, thyroid each case has radioactive. In normal pre-exposure imaging, a slight uptake of 30% (6/20) in the lung was also found with ~ (99m) Tc-sulfur colloid, with none of the microalbumin colloids