钢管结构是工程中常用的一种屋盖结构形式,在实际工程中由于型材定尺生产、加工下料、运输等原因,大量杆件本身需要相互连接。而现有现场焊接连接、法兰连接和螺栓拼接存在施工质量难以保证和视觉不美观等缺点,为改善该种连接节点,提出一种内置刚性连接方式,并进行3个试件的轴心受压试验。研究结果表明,内置刚性连接方式可有效传递轴力,但由于连接处存在截面突变,容易引起应力集中和应力分布不均现象,在设计时应该考虑由此引起的剪切滞后效应。
Steel pipe structure is commonly used in engineering, a form of roof structure, in the actual project due to the length of the profile production, processing and feeding, transportation and other reasons, a large number of pieces need to be connected to each other. However, existing on-site welding connections, flange connections and bolt splicing have disadvantages such as poor construction quality and poor visual appearance. In order to improve the connection node, a rigid connection is provided and the axial center of the three test pieces Pressure test. The results show that the built-in rigid connection can effectively transmit the axial force. However, due to the sudden change of section, the stress concentration and the uneven distribution of stress are easily caused. In the design, the resulting shear lag effect should be considered.