第一部分包括W/石墨及Mo/石墨浸入式热电偶的试验工作。试验结果指出此种热电偶有用作测量钢水温度的可能。由于石墨灰分含量显著影响其所生的热电动势以及其他的原因,此种浸入式热电偶尚须进一步研究。第二部分包括W/Mo浸入式热电偶的试验。此种热电偶以石墨为保护管。试验指出W/Mo的热电动势与温度的关系,在1400℃以上时成近似直线,所生之热电动势为正值。在此温度以上热电动势的产生药为6.6μV/℃。W/Mo有相当的正确性及稳定性。每次测温约在1分10秒内。石墨保护管可用4次。此种热电偶经研究所及现厂试验结果,认为可以推广。
The first part includes experimental work on W / graphite and Mo / graphite immersion thermocouples. Test results indicate that this type of thermocouple may be used as a measure of the temperature of molten steel. Due to graphite ash content significantly affect the thermoelectromotive force and other reasons, the immersion thermocouple needs further study. The second part includes the W / Mo immersion thermocouple test. This thermocouple with graphite as a protective tube. It is pointed out that the relationship between the thermoelectromotive force and the temperature of W / Mo is approximately linear when it is above 1400 ℃, and the thermoelectromotive force generated is positive. Above this temperature, the generation of thermoelectromotive force is 6.6μV / ℃. W / Mo is quite correct and stable. Each temperature is about 1 minute 10 seconds. Graphite protection tube available 4 times. The thermocouple by the Institute and the factory test results, that can be promoted.